2 Small Form Factor Pluggable Plus (SFP+) 1 GbE/10 GbE ports
Additional ports and slots
1 RJ-45 serial console port
1 RJ-45 Out-of-Band management port
1 USB 2.0
Power supplies
2 power supply slots
1 minimum power supply required (Ordered separately)
Fan tray
6 fan tray slots
The user must order fan trays, as fan trays are
not included with the switch. This system requires Same-Direction
airflow fan trays to function properly
The system should not be operated with only five
fan trays for more than 24 hrs. The system should not be operated
without a fan tray for more than two minutes
Physical characteristics
Dimensions (H x W x D): 4.36 x 44.00 x 54.00 cm (1.72 x 17.32 x 25.98 in)
Operating relative humidity: 10% to 95%, non-Condensing
Acoustic: Low-Speed fan: 62.8 dB, high-speed fan: 78.2 dB
Electrical characteristics
Frequency: 50/60 Hz
Maximum heat dissipation: 955/1689 BTU/hr (1007.53/1781.9 kJ/hr)
Voltage: 90 - 264 V ac, rated
(-40) - (-75) V dc, rated (Depending on power supply chosen)
Maximum power rating: 495 W
Idle power: 280 W
NOTE: Idle power is the actual power
consumption of the device with no ports connected. Maximum power rating
and maximum heat dissipation are the worstcase theoretical maximum
numbers provided for planning the infrastructure with fully loaded power
over Ethernet (PoE) (If equipped), 100% traffic, all ports plugged in,
and all modules populated
Safety
UL 60950-1
EN 60825-1 Safety of Laser Products-Part 1
EN 60825-2 Safety of Laser Products- Part 2
IEC 60950-1
CAN/CSA-C22.2 No. 60950-1
Anatel
ULAR
GOST
EN 60950-1/A11
FDA 21 CFR Subchapter J
NOM
ROHS compliance
Emissions
VCCI class A
EN 55022 class A
ICES-003 class A
ANSI C63.4 2003
AS/NZS CISPR 22 class A
EN 61000-3-2:2006
EN 61000-3-3:1995 +A1:2001+A2:2005
EMC Directive 2004/108/EC
FCC (CFR 47, Part 15) class A
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
Immunity
Generic: ETSI EN 300 386 V1.3.3
EN: EN 55024:1998+ A1:2001 + A2:2003
ESD: EN 61000-4-2; IEC 61000-4-2
Radiated: EN 61000-4-3; IEC 61000-4-3
EFT/Burst: EN 61000-4-4; IEC 61000-4-4
Surge: EN 61000-4-5; IEC 61000-4-5
Conducted: EN 61000-4-6; IEC 61000-4-6
Power frequency magnetic field: IEC 61000-4-8; EN 61000-4-8
Voltage dips and interruptions: EN 61000-4-11; IEC 61000-4-11
Harmonics: EN 61000-3-2, IEC 61000-3-2
Flicker: EN 61000-3-3, IEC 61000-3-3
Management
Intelligent Management Center (IMC)
Command-Line Interface (CLI)
Out-of-Band management
Simple Network Management Protocol (SNMP) manager
Telnet
File Transfer Protocol (FTP)
We ship all products according to manufacturer specifications. If the manufacturer does not include an option as standard with the product (power supply, fan tray etc) we do not either unless specifically stated. If you are have questions regarding what is included with a product, please contact us.